-232w%20(1).png)
Case Study 1 - Penpole Lane, Avonmouth, Bristol, BS11 0AU
Problem: The property showed signs of moisture staining, and high readings confirmed structural rising damp.
​
Solution: We removed the affected plaster, injected a damp proof course and vertical barriers using diffused injection cream to BS6576 standards, and re-plastered with a sand/cement mix incorporating a cementitious tanking compound.
Result: The property now has a fully protected wall system, preventing further rising damp and ensuring a long-lasting finish.

Case Study 2 – Kimberley Road, Fishponds, Bristol, BS16 5AE
Problem: Damp issues were affecting the internal walls, requiring a breathable damp-proofing approach.
​
Solution: We hacked off the plaster, injected a damp proof course and vertical barriers with injection cream to BS6576, and re-plastered using breathable renovating plaster and finishes.
Result: The breathable system provides strong protection against damp while allowing the walls to perform naturally.

Case Study 3 – Green Street, Totterdown, Bristol, BS3 4UB
Problem: Damp was affecting the property, with a need for a sympathetic and breathable solution.
​
Solution: Our team removed the plaster, installed a damp proof course and vertical barriers using injection cream to BS6576, and applied breathable renovating plaster in line with our waterproofing specification.
Result: The home now benefits from effective damp protection while retaining wall breathability.

Case Study 4 – Rozel Road, Horfield, Bristol, BS7 8SQ
Problem: The property required preventative damp-proofing to avoid further damage.
​
Solution: We hacked off the plaster, injected a precautionary damp proof course and vertical barriers to BS6576, and re-plastered using a robust sand/cement system.
Result: The property is safeguarded with a long-term barrier against damp.

​Case Study 5 – Highbury Road, Bedminster, Bristol, BS3 5NS
Problem: Problem: Rising damp was causing deterioration to the internal walls.
​
Solution: We removed the plaster, installed a damp proof course and vertical barriers using injection cream to BS6576, and re-plastered to our specification with sand/cement.
​
Results: The walls were restored to a dry, sound condition with long-lasting protection

Case Study 6 – Victoria Walk, Cotham, Bristol, BS6 5ST
Problem: A storage room with a vaulted ceiling was suffering from water ingress and condensation.​
​
Solution: We removed the render, applied a tanking compound, prepared the floor/wall junction, installed a cavity drainage membrane (CDM), and re-plastered with sand/cement.
​
Result: The storage room is now dry, usable, and fully protected against further water ingress.
​
Client Review: “ADC carried out damp proofing work on an underground room, and I’m impressed with the results. The team was professional, tidy, and efficient. They were always available to answer any questions I had, and took the time to explain each step clearly, which gave me real confidence in the work being done. I would recommend them.”
​

Case Study 7 – Oaklands Drive, Almondsbury, Bristol, BS32 4AB
Problem: The property required damp-proofing and insulation improvements.
​
Solution: We removed the plaster, injected a damp proof course and vertical barriers using injection cream to BS6576, re-plastered with sand/cement, and fitted 27mm XP thermal boards.
​
Results: The property now benefits from both damp protection and improved thermal efficiency.

Case Study 8 – Glebe Road, Ashton, BS41 9LH
Problem: A garage was suffering from penetrating damp through the floor.​
​
Solution: We excavated a trench around the garage, installed a damp-proof membrane (DPM), and re-laid the floor.
​
Result: The garage is now fully protected against water ingress, ensuring a dry and durable space.​
​